Adjustable Immersion
Compression fitting allows the probe insertion depth to be adjusted during installation for the required measuring location
Adjustable Probe Thermocouple with Connection Head for Reliable Industrial Process Temperature
The TC71 MGO-PAC Industrial Thermocouple provides reliable process temperature measurement with the flexibility of an adjustable compression fitting and protected connection head. Its mineral-insulated MGO-PAC construction is designed for demanding industrial service, while configurable thermocouple types, sheath materials, junction styles, and immersion lengths allow the assembly to be matched to the application. The connection head can accommodate a terminal block, 4–20 mA transmitter, or HART transmitter, providing flexible integration with plant instrumentation and control systems

Compression fitting allows the probe insertion depth to be adjusted during installation for the required measuring location

Compact mineral-insulated construction provides a durable sensing assembly for demanding industrial temperature measurement

Engineered for reliable and stable temperature measurement in demanding high-temperature industrial processes and equipment.

Connection-head construction provides a practical termination point while helping protect field wiring and electrical connections

The connection head can accommodate a ceramic terminal block, standard 4–20 mA transmitter, or 4–20 mA HART transmitter for integration with process control systems

Thermocouple type, sheath diameter, sheath material, immersion length, process fitting, measuring junction, connection head, and output configuration can be selected around the installation requirements
Oil & Gas
Petrochemical
Power Generation
Pulp & Paper
Food & Beverage
Pharmaceutical
Industrial Furnaces
OEM
Review the standard specifications and available configuration options for the TC71 Industrial adjustable Thermocouple with connection head. Product dimensions, materials, temperature ratings, and optional features may vary depending on the selected configuration
Technical specifications, dimensions, ordering information, and configuration options for the TC71 Thermocouple

Installation, wiring, maintenance, and troubleshooting instructions for the TC71 Thermocouple.
Download file →
Instructions d'installation, de câblage, de maintenance et de dépannage pour le thermocouple de palier TC71
Download file →Complete your installation with compatible mounting accessories, connectors, and replacement components for the TC71 Thermocouple.

Thermocouple fitting is used in applications where a thermocouple needs to be connected to a an application, control system, or other measurement instruments. The fitting ensures that the thermocouple wire is securely…
Find more…
TempoTech’s Thermocouple connection heads are enclosures designed to house the thermocouple junction and provide a safe, protected environment for the connections to the temperature measurement system. These heads are typically used in…
Find more…
In industries where accuracy is crucial and time is of the essence, the Head Mount Transmitter with -USB proves to be a dependable choice for temperature measurement. This versatile, loop-powered transmitter, designed…
Find more…
The TT-267 temperature transmitters are engineered for versatile use in the process industry, delivering exceptional accuracy with sensor-transmitter matching and robust protection against electromagnetic interference. Configurable via the HART® protocol, these transmitters…
Find more…
The TT-367 temperature transmitters are engineered for versatile use in the process industry, delivering exceptional accuracy with sensor-transmitter matching and robust protection against electromagnetic interference. Configurable via the HART® protocol, these transmitters…
Find more…Watch product overview, installation, and application videos for the TC71 Thermocouple
A temperature transmitter takes the temperature data from a sensor, like an RTD or thermocouple, and converts it into a standard signal, usually 4-20mA or 0-10V. This signal can be sent to control systems, PLCs, or monitoring equipment to keep track of temperature in real-time.
Video Transcription: Temperature Transmitter Technology & Application
[00:05] A temperature transmitter is a critical component in industrial automation that converts low-level sensor signals into standardized outputs. This ensures accurate, reliable, and long-distance signal transmission for complex control systems.
[00:14] Thermocouple and RTD sensors are the industry standards for measuring the temperature of processed media. However, in challenging environments—characterized by high temperatures, electromagnetic interference (EMI), or long cable runs—the raw signals from these sensors can degrade.
[00:33] This signal degradation, often caused by wire resistance and electrical noise, can lead to inaccurate readings. To mitigate these issues, temperature transmitters are used to amplify, condition, and convert sensor data into a standardized 4-20mA output, ensuring high-integrity data across the plant.
[00:59] Several signal types are used depending on the application:
4 to 20 mA Analog Signal: The most common standard, highly resistant to noise and ideal for long distances.
0 to 10V: A common analog option, though more susceptible to signal loss over length.
Digital Signals (HART & Modbus): Used for advanced remote communication and diagnostics.
RS485/RS232: Essential for integrating transmitters with PLCs and SCADA systems.
[01:35] The Tempotech TT367 series temperature transmitters are engineered for versatility. They offer precise sensor-transmitter matching and robust protection against interference. Configurable via the HART protocol, these units allow for easy setup and reliable field operation.
[01:56] Key reliability features include open/short-circuit detection, incorrect wiring alerts, and NAMUR NE43 failure standards. The TT367 supports RTD, TC, Ohm, and Millivolt inputs, making it a universal solution for your instrumentation needs.
[02:26] With integrated dot-matrix displays and easy configuration options, our transmitters provide the precision you can trust. Contact our technical sales team today to find the best transmitter for your application.
A thermowell is a protective casing that houses temperature sensors like RTDs or thermocouples, keeping them safe from high pressure, corrosion, or physical damage. It allows you to measure temperature in harsh environments without worrying about damaging the sensor itself.
[00:04] A thermowell plays a critical role in protecting temperature sensors, ensuring system safety, and extending the lifespan of your equipment. It also enables easy sensor maintenance without depressurizing the system.
[00:15] To achieve reliable readings, it is essential to understand proper thermowell placement and industry best practices.
[00:23] A primary rule of thumb for insertion length is to insert the thermowell 1/3 to 2/3 of the way into the process fluid. Alternatively, consider an insertion length 10 times the thermowell tip diameter, or at least 2 inches into the process media.
[00:33] Caution is required: excessive thermowell length can cause vibration from fluid flow, leading to resonance, mechanical fatigue, and potential failure. Conversely, a thermowell that is too short results in poor heat transfer, leading to a slow response time and unreliable temperature data.
[00:55] For inline installation, thermowells should be offset at angles to avoid interference and allow for easy maintenance access.
[01:06] Maintain a spacing of 10 to 100 times the pipe diameter (typically 25 times) to ensure accurate readings and maintain laminar flow within the process.
[01:16] In elbow installations, the thermowell can face upstream to avoid mixing and swirling effects, or downstream where flow turbulence may influence the sensor. Upstream installation is generally preferred for maximum accuracy.
[01:35] Other critical factors to consider include pipe size, the type of process fluid, flow velocity, and distance from surrounding instruments.
[01:46] Thanks for watching this guide. For high-quality ANSI-standard thermowells and sensors, visit www.tempotechcontrols.com.
Open the product configurator to select available options and prepare your configuration.
Find answers to common questions about the TC71 Thermocouple
Yes. The adjustable process fitting allows the TC71 to be used with or without a thermowell, depending on the process and installation design. When a thermowell is required, the probe and fitting should be selected to suit the thermowell dimensions and connection
he adjustable fitting allows the immersion depth to be set during installation rather than requiring a fixed insertion length. This is useful when matching an existing thermowell, positioning the sensing tip correctly, or standardizing one probe design across installations with different insertion requirements
Choose grounded when faster response and rugged construction are priorities and electrical isolation is not required. Choose ungrounded when the thermocouple junction should be electrically isolated from the sheath. If electrical grounding conditions are uncertain and very fast response is not required, an ungrounded junction is often the more appropriate starting point for review
The compression fitting provides an adjustable process connection, but whether the probe should be repositioned after commissioning depends on the fitting, ferrule, and installation. The product information does not state that every configuration is repeatedly repositionable, so this should be considered when selecting the fitting and ferrule
Both stainless steel and Teflon ferrule options are available. The correct selection depends on the required installation, temperature, sealing arrangement, and whether adjustability after initial installation is important.
Yes. The TC71 is available in duplex grounded, duplex ungrounded, and duplex exposed configurations. A duplex element provides two thermocouple circuits from the same assembly for applications requiring separate instrumentation or redundant measurement
The TC71 should not be treated as a pressure-rated instrument by itself. For installations on pressure-containing equipment, use an appropriately engineered thermowell or process connection where required. The complete installation should be reviewed by the responsible design engineer for the process pressure, temperature, media, materials, and applicable design requirements.
Provide the thermocouple type, grounded/ungrounded/exposed junction, simplex or duplex configuration, sheath diameter and material, immersion length, connection head, conduit connection, adjustable fitting material and thread, ferrule material, and head termination. If a thermowell is required, provide the thermowell requirements as part of the assembly selection.