Description
– Input Sensor: configurable
– Pt100: 2, 3 or 4-wire, 0.170 mA excitation current, Alpha = 0.00385 according to IEC 751(NBR 13773)
– Voltage: 0 to 50 mVdc. Impedance > 1 MΩ
– Total Accuracy: maximum error of 0.3 % of maximum range for thermocouples; 0.2 % of maximum range for Pt100 and voltage
– Response Time: ≤500 ms
– Isolation: 1000 Vac for 1 minute between input and output
– Output: 4-20 mA current or 20-4 mA, two-wire type; linear in respect to the measured temperature
– Output Resolution: 0.004 mA (12 bits)
– Power: 12 to 35 Vdc, voltage over the transmitter
– Maximum Load in series: RL= (Vdc – 12) / 0.02 Ω where Vdc is the power voltage
– Operating Temperature: -20 to 75 °C
– Relative Humidity: 0 to 90 % RH
– Eletromagnetic Compatibility: EN 50081-2, EN 50082-2
– Internal protection against reversed power voltage polarity
– Internal cold junction compensation for thermocouples
– ABS enclosure, 44 mm diameter and 24 mm maximum height
– Communication cable: mini-B USB cable, 5 pins