Input type | Universal input: thermocouple, RTD, voltage, current, mV |
Sampling rate | 50 ms |
Accuracy | Thermocouple input: either ±1°C ±1 digit or ±0.3% of indicated value ±1 digit, whichever is larger |
RTD input: ±0.2% of indication value ±1 digit or ±0.8°C ± 1 digit, whichever is larger |
Voltage and current input: ±0.3% FS ± 1digit |
Control cycle | 0.1 s to 99 s |
Output type | Relay contact output, SSR/SSC drive output, current output, voltage output, motor-operated valve control output |
Control | ON/OFF, PID, PID2, fuzzy, 2-degrees-of-freedom PID, |
auto tuning, self tuning |
Communication | Communication port x 1 (for optional USB cable) |
RS-485 port x 1 (Modbus RTU protocol) |
Other functions | Ramp soak (simple program control): up to 64 steps |
SV/PID selection: up to 8 groups |
Soft start |
User-defined keys |
Auto/manual switching |
Simple watt-hour monitoring |
Operating days alarm |
Heating/cooling control (option) |
Alarm (option) |
Multidrop control via RS-485 network, parameter copy, program less communication |
Contact output (option) | up to 5 (PXF4: up to 3) |
Contact input (option) | up to 3 (PXF4: up to 1) |
Transfer output (option) | Output signal: voltage or current |
CT input (option) | for heater break alarm or watt-hour metering. |
Current transformer (for 1–100 A) is optional. |
Remote SV input (option) | Input signal: voltage or current |
Display | M. V. A. LCD, 4-color, white PV display |
Dimensions (W x H x D) | PXF4: 48 × 48 × 65.7 mm |
PXF5: 48 × 96 × 65.7 mm |
PXF9: 96 × 96 × 65.7 mm |
Power supply voltage | 100–240 V AC, 50/60 Hz, 24 V AC/DC |
Enclosure | Front waterproof (when watertight packing is used), IP 66 equivalent |